- INPUT
- Input signal : Bridge voltage from load cell
- Rated ouput from strain guage : 1~20mV/V
- Excitation voltage : 10V standard and others
- Permissible current : 35mV at 10V max
- INSTALLATION
- Operationg temperature : -5¡É ~ 55¡É
- Operationg Humidity : 90%RH Max
(none condensing)
- Power supply
- AC : 110V or 220V/60Hz ¡¾10%, approx 3VA
- DC : 18V ~ 30V ¡¾10%, approx 3VA
- Power selection : AC 110V/220V Switch
in the back plane
- Mounting : Wall or DIN rail
- PERFORMANCE
- Accuracy : ¡¾ 0.2% of full scale
- Temp'coefficient : ¡¾0.015¡É
- Response time : 0.5 Sec or less (0~90%)
- Insulation resistance : 100M¥Ø or more
with DC 500V (Input/Output/Power)
- Dielectric strength : 1500VAC at 1 minute
(Input to Output to Power)
|
- OUTPUT
- DC VOLTAGE : ¡¾ 12V Max
- Load Resistance
|
Output |
Resistance |
|
0 ~ 10mV |
1K¥Ø or more |
|
0 ~ 100mV |
1K¥Ø or more |
|
0 ~ 1V |
1K¥Ø or more |
|
0 ~ 5V |
2K¥Ø or more |
|
0 ~ 10V |
4K¥Ø or more |
|
-10V ~ 10V |
4K¥Ø or more |
- DC CURRENT : 0 ~ 20mA
- Load Rsistance
|
Output |
Resistance |
|
0 ~ 1mA |
15K¥Ø or less |
|
0 ~ 10mA |
1.5K¥Ø or less |
|
0 ~ 20mA |
750¥Ø or less |
|
1 ~ 5mA |
3K¥Ø or less |
|
4 ~ 20mA |
750¥Ø or less |
- Display range : -999 ~ 1999,3 1/2 digit
( available decimal point )
|